In a cyclone dust collector, the dust-laden gas stream-driven by a fan-enters the collector's volute casing tangentially at a high velocity, moving in a downward spiral. Under the influence of centrifugal force, dust particles are directed toward the central axis, where they spiral upward and are discharged through the central core tube. Meanwhile, dust particles near the outer wall-pushed by gravity and the downward airflow-descend along the wall surface into a dust hopper, thereby achieving dust removal.
A baghouse dust collector utilizes a microprocessor-based control system to manage compartment-specific reverse-pulse cleaning on a timed schedule. The system is also equipped with temperature monitoring, a digital display, and an over-temperature alarm. The filter bags are made of CW300-FcA anti-condensation fiberglass, which effectively prevents condensation and protects the bags from heat damage, ensuring both high dust-removal efficiency and operational safety.
An electrostatic precipitator (ESP) operates by converting 50Hz, 220V AC power into high-voltage DC (exceeding 100kV), which is applied to the corona electrodes (cathodes) to generate a non-uniform high-voltage electric field. This field ionizes the gas, producing a large number of negative ions and electrons. As dust particles enter the electric field, they become electrically charged and are driven by electrostatic forces toward the opposing electrodes (anode collection plates). Finally, the collected dust is dislodged via a rapping mechanism, falling into a dust hopper for removal, thus completing the purification process.